Smoke detector installation sites and positioning


!±8± Smoke detector installation sites and positioning

Where to install a smoke detector and its positioning are as important as this life saving device ever installed. Could delay the placement of a smoke detector in a false answer to smoking or even prevent an alarm sounds at all.

Although, you must install smoke alarms following the guidelines of the equipment manufacturer, and standards of NFPA (National Fire Protection Association), the local jurisdiction may have a different idea. This idea is usually lessSmoke detectors - Chicago is one of the examples.

Why is your life we're talking about, after only a minimum requirement is not enough - literally a few dollars more, you can use a maximum protection.

The correct placement of smoke detectors in the IRC (International Residential Code), IBC (International Building Code) and NFPA based on:

New construction:

Smoke detectors must be wired (powered from the electrical box) and require battery backup. TheirJurisdiction may require a dedicated circuit for this purpose - unless it is necessary, make sure you install smoke detectors is not a circuit / socket used to wall or ceiling light controlled. Put a smoke detector is on a GFCI protected, also not a good idea. Do not use rechargeable batteries for smoke detectors, is of good quality alkaline battery, type the correct choice. Smoke detectors are emitting a signal when theThe batteries are dead - Replace the battery with a new one as soon as you hear that sound repetitive. Smoke detectors are required in each sleeping area and adjacent bedroom. As I mentioned above, some countries require less - Chicago is one of the cases where smoke detectors are not in the bedroom / sleeping area is required. Instead, you must install a smoke detector within 15 'from the bedroom entrance. In large houses / apartments where bedrooms are located more than 30 'except, perhaps two or more smoke detectors should be installed. At least one is required on each floor of the house and cellar. Crawl spaces and attics uninhabitable do not need to install the smoke detector. However, in the attic or crawl a furnace, water heater, or devices, the fire source (gas, oil, electricity) may contain, have a smoke detector, and (in some jurisdictions, and highly recommended, if not installed required). SmokeDetectors must be interconnected - triggered a smoke detector activates all. Not all types of smoke detectors have the function of "interconnection", which is very important - part of smoking in the house would be to enable the next device, and automatically all of them at the same time.

Existing building:

During the renovation, the fixed wiring and connection of smoke detectors is not required if completed would be removed. However, you can still getmaximum protection with a wireless alarm system interconnected with smoke.

The smoke alarm shall be clearly audible in all locked rooms over background noise levels with all intervening doors. Therefore, regular testing of smoke alarms siren is so important - like any other mechanical / electronic - sometimes fail. Enclosed internal stairs will also require a smoke detector will be installed on the ceiling and the floor. Scales behave likeChimneys and smoke from the lower floor, which activates the device of an early warning system.

Smoke Detector Placement - Rules apply to all the above websites.
This is extremely important and at the same time very simple, unfortunately, because very often completely wrong. It 's probably because we do not like reading manuals often assume we know what we're doing.

When installing a smoke detector on the ceiling (the preferred location / might be neededin some countries), instead of doing it as close as possible to the center, never closer than 4 "(10 cm) on the side wall or in a corner. If for some reason it is not practical in the ceiling and wall installations are allowed, you can install smoke detectors on the wall with the top edge to a minimum 4 "(10 cm) and a maximum of 12" (30.5 cm) below the ceiling.

Before putting a smoke detector on the ceiling or wall, if the review of building insulation. Older houses may not haveCeiling (when open to the attic) or external wall insulation. This would allow for extreme heat or cold transfer from outside the house, creating a thermal barrier and prevent smoke from reaching / alarm. If this is the case (it is easy to wall or ceiling in very hot or cold), installing a smoke detector on a wall inside the house.

Install smoke detectors in rooms with cathedral, oblique, pointed, gabled ceiling or 3 'from the highest point(Measured horizontally). Install smoke detectors in every room of the territory / which was divided by a partial wall. The wall can come down from the ceiling (at least 24 ") or from the ground. Install smoke detectors on a tray-shaped cover (also known as the coffered ceiling), the highest part of the ceiling or on the slanted part of the ceiling 12 "(30.5 cm) vertically down from the highest point .

DO NOT install smoke detectors in the following areas to minimizePossibility of false alarms:

The areas where combustion particles are present (particle combustion - by-products of combustion) Garage poorly ventilated kitchen near furnaces and water heaters - I would not agree with this is because the presence of these particles would be a sign of combustion problems If you have one installed in these areas may, optical smoke detectors of a less annoying. Wet or very humid areas like bathrooms.The moisture after a hot shower can lead to a false alarm. Within 3 'of the hot air heating and / or cooling vents, direct air flow, close the whole house fan sites. High airflow could blow them away from the smoke detector or if it has not been properly or at all. Near fluorescent lights, in which electronic "noise" cause false alarms. Dusty areas where dust particles could cause smokeThe failure or false alarm In areas where the temperature can drop below 40 degrees F (4 ° C) or exceed 100 ° F (38 ° C) Avoid areas near the doors and windows during the installation of smoke detectors

When you get this far, I hope you have more than a general idea of ​​where to install smoke detectors in the house, and what is the optimal placement of smoke detectors.


Smoke detector installation sites and positioning